Comparison between Series (S) and Nominal Pressure (PN) DIN 8077:1999 Norm. | ||||
NP | SDR | S | ||
6 | 17.6 | 8.3 | ||
10 | 11 | 5 | ||
16 | 7.4 | 3.2 | ||
20 | 6 | 2.5 | ||
25 | 5 | 2 |
Nominal pressure and continual service during 50 years | ||||
IPS Product | Service Pressure and Working temperature | Maximum resistance to pressure | NP | S |
IPS Thread Fittings | 18.6 Kgf/cm2 at 20ºC | 120 Kgf/cm2 | 16 | 3.2 |
IPS Thread | 11.7 Kgf/cm2 at 20ºC | 100 Kgf/cm2 | 10 | 5 |
4x4 Plus | 11.7 Kgf/cm2 at 20ºC | 100 Kgf/cm2 | 10 | 5 |
Pressure Table* | |||||
---|---|---|---|---|---|
System | Tube Diameter | Continuous Working Pressure | |||
IPS Fusion System (Multilayer Tube S3,2) Standard: DIN 8077/IRAM 13470 | 20º C | 70º C | |||
½" | 10 Bar | 3.5 Bar | |||
¾" | 10 Bar | 3.5 Bar | |||
1" | 10 Bar | 3.5 Bar | |||
1¼" | 10 Bar | 3.5 Bar | |||
1½" | 8 Bar | 3 Bar | |||
2" | 8 Bar | 3 Bar | |||
2½" | 4 Bar | 2.5 Bar | |||
3" | 4 Bar | 2.5 Bar | |||
4" | 4 Bar | 2.5 Bar |